NEWater is the brand name given to highly treated reclaimed water produced by Singapore's Public Utilities Board (PUB). NEWater is produced by further purifying conventionally treated wastewater through microfiltration, reverse osmosis and ultraviolet radiation. The water is of potable quality and can be added to drinking water supply reservoirs, where it is withdrawn and treated again in conventional water treatment plants before being distributed to consumers. However, most NEWater is currently used for non-drinking purposes, mostly by industries with production requirements for high-purity water.[1]

As NEWater is ultra-pure and virtually free of minerals, it is highly sought after by electronics manufacturing and wafer fabrication plants, where even the tiniest speck of mineral dust in standard water can ruin a microchip. It is significantly cleaner than normal tap water and exceeds the drinking water standards set by both the World Health Organization (WHO) and the United States Environmental Protection Agency (USEPA). While it is perfectly safe to drink straight from the bottle, most of it is directed to these industries, leaving more standard tap water available for domestic homes.[1]

History

File:NEWater Bottle NDP 2014.jpeg
Bottle of NEWater that was given out during NDP 2014.

Singapore considered water recycling to complement its limited fresh water supply starting in the 1970s.[2] A Master Plan drafted in 1972 identified water reclamation and desalination as alternatives to reduce and eventually eliminate dependence on imported water from neighbouring Malaysia. Subsequently, a pre-NEWater experimental water reclamation treatment plant was built in 1974 that was terminated after a year.[3]

In 1998, the PUB and the Ministry of the Environment and Water Resources (MEWR) initiated the Singapore Water Reclamation Study (NEWater Study).[4] The aim was to determine if NEWater was a viable source of raw water for Singapore's needs. Both NEWater and desalination were explored to reduce reliance on water imported from Malaysia. This supply has long been a source of diplomatic friction between the two nations, and the Singaporean government was determined to avoid being vulnerable to foreign resource dependencies.[5] Although the Malaysian government is treaty-bound to supply water to Singapore until 2061, it has no obligation to continue doing so after that date. Consequently, Singapore aims to eliminate this resource dependency well ahead of the 2061 deadline. This dependency is also mutual, as Malaysia also relies on Singapore for treated water. Under the 1962 Water Agreement, Singapore is obligated to provide Johor with treated water, which Singapore supplies at a fraction of the actual treatment cost.[6]

In 2001, PUB initiated efforts to identify non-potable uses of water. NEWater, because of its high quality, became the supply of choice for industry demands. This use provided an outlet for this new water supply without increasing the demand on the limited potable water supply.[7]

The PUB launched NEWater to the public in 2003, with the opening of the first two NEWater plants - the Bedok and Kranji plants - as well as the NEWater Visitor Centre.[8] In anticipation of the potential public concerns over the safety of recycled water, NEWater was carefully implemented. The PUB was cautious in its usage of terms, avoiding terms such as 'wastewater' or 'sewage' that carried a negative connotation.[9] Sewage treatment plants were renamed to 'water reclamation plants' and sewage or wastewater were referred to as 'used water'. This contributed to a positive framing of NEWater, enhancing public acceptance of reused water. In addition, the government extensively engaged the public through exhibitions and advertisements to educate them about NEWater. The NEWater Visitor Centre, which allows people to view the NEWater treatment process, was also opened to enhance visitors' understanding of how NEWater is produced. These public engagement efforts were aimed at correcting any misunderstandings people might have towards recycled water and increasing public support for reused water.[10]

Also, innovative technologies which was promoted by international industries applied on NEWater, such as LG Chem[11] and DuPont[12] in its reverse osmosis technologies.

Production

File:NEWater S.C.A.D.A. room.jpg
Supervisory Control And Data Acquisition (S.C.A.D.A.) room at a NEWater plant
File:NEWater Bedok plant.jpg
Bedok NEWater Factory

The first NEWater plant was completed in May 2000. Singapore currently has four operational NEWater factories, at Bedok, Kranji, Ulu Pandan and Changi. The Bedok and Kranji factories were commissioned in 2002, the Ulu Pandan plant in March 2007 and the Changi plant in August 2009.[13][14] A plant at Seletar, commissioned in February 2004, was closed in 2011,[15] as the PUB implemented its plan to centralize the treatment of used water, under the Deep Tunnel Sewerage System.[16] In January 2017, a new NEWater plant was launched at Changi, and is the first plant to be jointly developed by a foreign and local company.[17]

The Bedok and Kranji plants are operated by the PUB, while the Ulu Pandan and Changi plants are under DBOO concessions by Keppel Seghers[18] and Sembcorp Industries.[19]

There is a Visitor Centre in the NEWater factory in Bedok, near the Singapore Expo Tanah Merah MRT station. The visitor centre was awarded the Best Sightseeing/Leisure/Educational Programme at the 20th Tourism Awards 2005 and the IWA Marketing & Communication Award in 2006.[20]

The visitor centre provides multiple free programmes to educate the public regarding the technologies and production of NEWater:

  • NEWater Scientist Program – Students take on the role of NEWater Scientists and explore the visitor centre[21]
  • Outdoor Classroom – Host fun activities and experiments that help students learn about reverse osmosis and other NEWater processes[22]
  • Water Ambassadors – Small workshops that teach uniformed groups (i.e. National Cadet Corps and Scouts Association) skills to be water ambassadors[23]
Plant name Location Date of commission Capacity per day Operator
Bedok NEWater Factory Bedok December 2002 Decommissioned on 31 July 2024[24] PUB[25]
Changi Water Reclamation Plant Changi 2017 Template:Convert BEWG-UESH[26]
Keppel Seghers NEWater Plant Toh Tuck 2007 Template:Convert Keppel Seghers[27]
Kranji NEWater Factory Kranji 2002 Template:Convert PUB[28]
Seletar NEWater plant Seletar 2004 Decommissioned in 2011 PUB[29]
Sembcorp NEWater Plant Changi 2010 Template:Convert Sembcorp[30][31]

Procedure

NEWater source water comes from effluent of secondary sewage treatment plants.[32] The effluent passes through a multiple-barrier water reclamation process:[33][34]

  • The first stage of the NEWater production process uses microfiltration/ultrafiltration to remove suspended solids, colloidal particles, disease-causing bacteria, some viruses and protozoan cysts. The filtered water after passing through the membrane contains only dissolved salts and organic molecules.
  • The second stage of the NEWater production process uses reverse osmosis (RO). A semi-permeable membrane filters out contaminants such as bacteria, viruses, heavy metals, nitrates, chlorides, sulfates, disinfection by-products, aromatic hydrocarbons, and pesticides. NEWater is thus free from viruses and bacteria and contains very low levels of salts and organic matter. At this stage, the water is of potable quality.
  • The third stage of the NEWater production process is a safety precaution. UV disinfection is used to ensure that all organisms are inactivated and the purity of the water can be guaranteed. After adding some alkaline chemicals to restore the pH balance, NEWater is ready for use.

Since 2002, there have been pilot programs to consider replacing the activated sludge process of the secondary sewage treatment and the microfiltration/ultrafiltration stage of the NEWater with a membrane bioreactor process.[34]

Applications

The total capacity of the plants is about Template:Convert. About 6% of this is used for indirect potable use, equal to about 1% of Singapore's potable water requirement of Template:Convert. The rest is used at wafer fabrication plants and other non-potable applications in industries in Woodlands, Tampines, Pasir Ris, and Ang Mo Kio.

Government figures show that the country's NEWater plans can meet up to 40% of Singapore's current needs, and the figure is expected to go up to 55% by 2060.[35]

Potability

The quality of NEWater consistently exceeds the requirements set by USEPA and WHO guidelines and is cleaner than other water sources in Singapore.[36]

The following table compares the water quality of NEWater to the WHO and USEPA standards.[37]

Quality Chart
Water Quality Parameters NEWater USEPA /WHO Standards
colspan=3 Template:Rh |A) Physical
Turbidity (NTU) <5 5/5
Colour (Hazen Units) <5 15/15
Conductivity (μS/cm) <250 Not Specified
pH Value 7.0–8.5 6.5–8.5
Total Dissolved Solids (mg/L) <150 500/1000
Total Organic Carbon (mg/L) <0.5 -/-
Total Hardness (Template:Chem2)(mg/L) <50 Not Available
colspan=3 Template:Rh |B) Chemical (mg/L)
Ammoniacal nitrogen (as N) <1.0 -/1.2
Chloride (Cl) <20 250/250
Fluoride (F) <0.5 4/1.5
Nitrate (Template:Chem2) <15 10/11
Silica (Template:Chem2) <3 -/-
Sulphate (Template:Chem2) <5 250/250
Residual Chlorine (Cl, Total) <2 4/5
Total Trihalomethanes (as mg/L) <0.08 0.08/-
colspan=3 Template:Rh |C) Metals (mg/L)
Aluminum <0.1 0.05–0.2/0.2
Barium <0.1 2/0.7
Boron <0.5 -/0.5
Calcium 4 - 20 -/-
Copper <0.05 1.3/2
Iron <0.04 0.3/0.3
Manganese <0.05 0.05/0.4
Sodium <20 -/200
Strontium <0.1 -/-
Zinc <0.1 5/3
colspan=3 Template:Rh |D) Bacteriological
Total Coliform Bacteria (Counts/100 mL) Not detectable Not detectable
Enterovirus Not detectable Not detectable
Heterotrophic Plate Count (CFU/mL, 35 °C, 48 h) <300 <500/-

See also

References

Template:Reflist

Template:Singapore topics

  1. ↑ 1.0 1.1 {{#invoke:citation/CS1|citation |CitationClass=web }}
  2. ↑ Water management in Singapore. International Journal of Water Resources Development, 22(2), 227–240, p. 230
  3. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  4. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  5. ↑ Template:Cite journal
  6. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  7. ↑ History of NEWater Template:Webarchive
  8. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  9. ↑ Template:Cite journal
  10. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  11. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  12. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  13. ↑ The 3rd National Tap Template:Webarchive
  14. ↑ Template:Cite news
  15. ↑ A Complete Makeover Template:Webarchive
  16. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  17. ↑ Template:Cite news
  18. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  19. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  20. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  21. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  22. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  23. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  24. ↑ Template:Cite news
  25. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  26. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  27. ↑ Channelnewsasia:NEWater to supply 30% of Singapore's water needs by 2011: PM Template:Webarchive, retrieved on August 10, 2012
  28. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  29. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  30. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  31. ↑ Template:Cite news
  32. ↑ Template:Cite book
  33. ↑ Template:Cite journal
  34. ↑ 34.0 34.1 Template:Cite book
  35. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}
  36. ↑ Public Utilities Board, NEWater FAQ Template:Webarchive
  37. ↑ {{#invoke:citation/CS1|citation |CitationClass=web }}